- Sensors
- Temperature monitor TW 50/60
- Temperature monitor TW 03 S – Type 8432
- Electronic temperature monitor – Type 8433
- PT100 thermo sensor – Type 8433
- Electronic thermostat – Type 8434
- PT100 thermosensor – Type 8434
- Electronic thermostat in cable form – Type 8434
- PT100 thermosensor 2-wire and 3-wire cable connection – Type 8434
- Non-contact magnetic switch – Type 8441
- Current sensor – Type 8442
- Non-contact overhead wire contact TLC 4 – Type 8474
- Precipitation sensor – Type 8921
- Precipitation sensor – Type 8921
- Potential monitoring/-protection
- Mobile adjustment and test device – Type 8204
- Potential monitoring devices
- Display unit – Type 8540
- Voltage Monitors
- Voltage Signal Relays
- Potential Protection Devices
- for floating grounds with voltage monitoring – Type 8900
- for floating grounds with voltage monitoring – Type 8900
- for floating grounds with current control – Type 8901
- with low voltage limiter, surge arrester current monitoring and remote clearing function – Type 8901
- with SIEMENS low voltage limiter and surge arrester – Type 8901
- for open earthing with current monitoring and remote clearing – Type 8901
- for floating grounds with current control and LED indicator – Type 8901
- Voltage fuse – Type 8961
- Voltage Limiting Device – Type 8962
- Over Voltage Protector Type PSNP – Type 8963
- R/C combination – Type 8970
- Earthing device – Type 8971
- Special relays
- Switching amplifier
- Temperature monitoring – Type 8435-PT100
- Evaluation unit – Type KAG2
- Evaluation unit – Type 8480
- Evaluation unit – Type KAV1
- Switching amplifier – Type 8582
- Switching amplifier – Type 8582DCW
- Isolating switching amplifier – Type 8583
- Switching amplifier – Type 8586
- Mobile Test Device for non-contact overhead contact line switch
- Cable Monitoring Devices
- Points Heating Systems
- Current Monitoring/-supply
- Cabinets
- Accessories
- Individual Solutions
Description
The type 8435 temperature monitor also allows the monitoring of temperatures over longer distances, such as monitoring the surface temperatures of cables, monitoring the temperature inside bundles of cables and similar tasks.
The unit consists of a temperature sensor, the evaluation unit.
The temperature sensor convert the recorded temperature into a proportional resistance.
The necessary power is supplied from the evaluation unit. Two or three cores of the cable are required for operation of the sensor and transmission of the measured value. A shielded cable must be laid to the temperature sensor for cable lengths > 25 m and to avoid possible interference.
The evaluation unit converts the recorded temperature into a voltage of 0V to 10 V, corresponding to the range -50°C to 50°C. This voltage can be passed on to a voltmeter or a suitable measuring instrument that writes on paper.
Long-term monitoring can also be done in this way.
The unit also works as a limiting value monitor in addition to the display function. An output relay switches if the limit temperature (which can be set as desired) is exceeded. A zero-potential changeover contact are provided to pass on messages. The fact that the limiting value has been exceeded is indicated at the evaluation unit by a light emitting diode (LED).
A measurement voltage is provided at terminals for exact setting of the limiting values. A voltage of from 0 to 10 V = -50°C to 50°C is provided at these terminals to set the limiting value.
Additional temperature measuring monitoring equipment is available on request.
Do you have any questions?
We will be happy to answer you!