- Sensors
- Temperature monitor TW 50/60
- Temperature monitor TW 03 S – Type 8432
- Electronic temperature monitor – Type 8433
- PT100 thermo sensor – Type 8433
- Electronic thermostat – Type 8434
- PT100 thermosensor – Type 8434
- Electronic thermostat in cable form – Type 8434
- PT100 thermosensor 2-wire and 3-wire cable connection – Type 8434
- Non-contact magnetic switch – Type 8441
- Current sensor – Type 8442
- Non-contact overhead wire contact TLC 4 – Type 8474
- Precipitation sensor – Type 8921
- Precipitation sensor – Type 8921
- Potential monitoring/-protection
- Mobile adjustment and test device – Type 8204
- Potential monitoring devices
- Display unit – Type 8540
- Voltage Monitors
- Voltage Signal Relays
- Potential Protection Devices
- for floating grounds with voltage monitoring – Type 8900
- for floating grounds with voltage monitoring – Type 8900
- for floating grounds with current control – Type 8901
- with low voltage limiter, surge arrester current monitoring and remote clearing function – Type 8901
- with SIEMENS low voltage limiter and surge arrester – Type 8901
- for open earthing with current monitoring and remote clearing – Type 8901
- for floating grounds with current control and LED indicator – Type 8901
- Voltage fuse – Type 8961
- Voltage Limiting Device – Type 8962
- Over Voltage Protector Type PSNP – Type 8963
- R/C combination – Type 8970
- Earthing device – Type 8971
- Special relays
- Switching amplifier
- Temperature monitoring – Type 8435-PT100
- Evaluation unit – Type KAG2
- Evaluation unit – Type 8480
- Evaluation unit – Type KAV1
- Switching amplifier – Type 8582
- Switching amplifier – Type 8582DCW
- Isolating switching amplifier – Type 8583
- Switching amplifier – Type 8586
- Mobile Test Device for non-contact overhead contact line switch
- Cable Monitoring Devices
- Points Heating Systems
- Current Monitoring/-supply
- Cabinets
- Accessories
- Individual Solutions
Description
The type 8595 signal relay is a relay that can be used, without auxiliary voltage supply, on DC railway systems with a maximum direct voltage of 900 V. The influence of drops in voltage can be balanced out within certain limits.
As an output, the relay has two changeover dry contacts. The switching status of the relay is indicated by a LED.
The type 8595 signal relay has a switching power supply. Modern electronic components ensure the greatest range of voltage at the lowest power consumption. This guarantees the high safety standard and the stability of the individual characteristics as well as the relay as a whole.
Function
The type 8595 relay works without additional auxiliary voltage. It is powered directly from the measured voltage UM(+Kl. 11, -Kl. 13), which may be up to DC 900 V.
Via a jumper, the relay can be set externally via terminals 15-20 to five different switching points predefined depending on type.
If the selected switching point is exceeded, the two output relays are triggered.
The dry contacts can be used for control or signal instructions as desired.
An LED on the front panel shows the switching status of the relay.
The special electronic switching also allows for optimal adjustment to special operational problems.
Do you have any questions?
We will be happy to answer you!