- Sensors
- Temperature monitor TW 50/60
- Temperature monitor TW 03 S – Type 8432
- Electronic temperature monitor – Type 8433
- PT100 thermo sensor – Type 8433
- Electronic thermostat – Type 8434
- PT100 thermosensor – Type 8434
- Electronic thermostat in cable form – Type 8434
- PT100 thermosensor 2-wire and 3-wire cable connection – Type 8434
- Non-contact magnetic switch – Type 8441
- Current sensor – Type 8442
- Non-contact overhead wire contact TLC 4 – Type 8474
- Precipitation sensor – Type 8921
- Precipitation sensor – Type 8921
- Potential monitoring/-protection
- Mobile adjustment and test device – Type 8204
- Potential monitoring devices
- Display unit – Type 8540
- Voltage Monitors
- Voltage Signal Relays
- Potential Protection Devices
- for floating grounds with voltage monitoring – Type 8900
- for floating grounds with voltage monitoring – Type 8900
- for floating grounds with current control – Type 8901
- with low voltage limiter, surge arrester current monitoring and remote clearing function – Type 8901
- with SIEMENS low voltage limiter and surge arrester – Type 8901
- for open earthing with current monitoring and remote clearing – Type 8901
- for floating grounds with current control and LED indicator – Type 8901
- Voltage fuse – Type 8961
- Voltage Limiting Device – Type 8962
- Over Voltage Protector Type PSNP – Type 8963
- R/C combination – Type 8970
- Earthing device – Type 8971
- Special relays
- Switching amplifier
- Temperature monitoring – Type 8435-PT100
- Evaluation unit – Type KAG2
- Evaluation unit – Type 8480
- Evaluation unit – Type KAV1
- Switching amplifier – Type 8582
- Switching amplifier – Type 8582DCW
- Isolating switching amplifier – Type 8583
- Switching amplifier – Type 8586
- Mobile Test Device for non-contact overhead contact line switch
- Cable Monitoring Devices
- Points Heating Systems
- Current Monitoring/-supply
- Cabinets
- Accessories
- Individual Solutions
Description
In view of the option to specify the trigger value and the reset value in steps of 1°C within a wide measuring range (this must be specified explicitly when ordering), these thermostats (temperature sensors) or the 8434 series are especially suitable for applications that place high requirements concerning switching accuracy and reproducibility.
The robust construction permits reliable use at the rail as a precision thermostat for points heater controllers. The compact construction allows, for example, use as a two-step controller for switch cabinet heaters or as an overtemperature detector.
The temperature sensor is available in two different electrical versions. The two-core cable version in connection with suitable evaluation equipment (for example, the type 8582) as as a three-core cable version that triggers relays directly.
A fastening adapter, the type 913001, is available on request as an accessory for installation at the foot of the rail.
The new type of electrical quick-connection technology allows simple inventory without needing to worry about various cable lengths.
Function
The heart of the sensor is the temperature sensor whose digitized measured value is permanently compared with the one specified by the user and the switching thresholds that had been specified by the manufacturer. The switching state of the sensor changes if the measured temperature reachers the higher one of the two switching thresholds. This state is held until the temperature once again reaches the value of the lower switching threshold.
This change of switching state leads to a change in the power circuit in the version with a two-core cable and to a change in the switching state of the third core in the version with a three-core cable.
Installation notes
Remove about 15 mm of the cable insulation (see the technical data), push on the PG coupling ring, crown and sealing rubber piece (up to the edge of the insulation). Push the ends of the wires into the cutouts in the splicing ring (note the numbers, see the back of the ring), cut off the ends of the wires so that they are flush with the splicing ring. Guide the cable that has been prepared in this way into the contact holder and tighten up the coupling ring – done!
See the complete brochure folder for additional temperature monitors, evaluation equipment and accessories.
Do you have any questions?
We will be happy to answer you!