- Sensors
- Temperature monitor TW 50/60
- Temperature monitor TW 03 S – Type 8432
- Electronic temperature monitor – Type 8433
- PT100 thermo sensor – Type 8433
- Electronic thermostat – Type 8434
- PT100 thermosensor – Type 8434
- Electronic thermostat in cable form – Type 8434
- PT100 thermosensor 2-wire and 3-wire cable connection – Type 8434
- Non-contact magnetic switch – Type 8441
- Current sensor – Type 8442
- Non-contact overhead wire contact TLC 4 – Type 8474
- Precipitation sensor – Type 8921
- Precipitation sensor – Type 8921
- Potential monitoring/-protection
- Mobile adjustment and test device – Type 8204
- Potential monitoring devices
- Display unit – Type 8540
- Voltage Monitors
- Voltage Signal Relays
- Potential Protection Devices
- for floating grounds with voltage monitoring – Type 8900
- for floating grounds with voltage monitoring – Type 8900
- for floating grounds with current control – Type 8901
- with low voltage limiter, surge arrester current monitoring and remote clearing function – Type 8901
- with SIEMENS low voltage limiter and surge arrester – Type 8901
- for open earthing with current monitoring and remote clearing – Type 8901
- for floating grounds with current control and LED indicator – Type 8901
- Voltage fuse – Type 8961
- Voltage Limiting Device – Type 8962
- Over Voltage Protector Type PSNP – Type 8963
- R/C combination – Type 8970
- Earthing device – Type 8971
- Special relays
- Switching amplifier
- Temperature monitoring – Type 8435-PT100
- Evaluation unit – Type KAG2
- Evaluation unit – Type 8480
- Evaluation unit – Type KAV1
- Switching amplifier – Type 8582
- Switching amplifier – Type 8582DCW
- Isolating switching amplifier – Type 8583
- Switching amplifier – Type 8586
- Mobile Test Device for non-contact overhead contact line switch
- Cable Monitoring Devices
- Points Heating Systems
- Current Monitoring/-supply
- Cabinets
- Accessories
- Individual Solutions
Description
There are special problems with railways operating with DC power concerning contact and anti-corrosion protection and overvoltage protection (e.g. lightning). On the one hand, an attempt is made to prevent the DC currents from connecting to earth as far as possible so as to avoid corrosion, while on the other hand there is the problem that dangerous voltage potentials can arise between the two areas if a strict electrical separation is made.
Dangerous contact voltages can arise if these areas are spatially close to one another. This problem can be solved by using open earthing.
Low-voltage limiting units such as voltage-limiting devices connect the various power supply networks with one another when the trigger value is exceeded.
This thus ensures that no higher contact voltages than those planned can arise and lead to short circuits when connecting the various power supply networks for triggering. (See DIN EN 50122-1 and DIN EN 50123-5 – VDE 0115 Part 3 and Part 300-5 for further details.)
The following describes a complete solution with voltage-limiting devices. The monitoring of the voltage-limiting device is done via the flow of current through the voltage-limiting device (see brochure sheet 8900 for a complete solution with monitoring of the voltage-limiting device via the voltage differences at the voltage-limiting device).
The arrangement consists of 4 core items
1. type 8961 voltage-limiting unit
2. type 8546 current sensor
3. MO-surge arrester
4. inductance
The voltage-limiting device involves a fuse whose action is based on a spark gap (see brochure sheet 8961).
The voltage-limiting device is designed for a value of 120V.
Monitoring of the voltage-limiting device via the flow of current through the voltage-limiting device is always recommended if a message is required without a delay and if sufficiently large currents (more than 15 A) flow through the voltage-limiting device.
As opposed to voltage monitoring, the current monitoring device reacts at once. It is recommended that you store the message, since it only exists while the current is flowing. The current sensor type 8546 store the output until the reset input will be connected with 24VDC.
When testing the voltage-limiting device to determine its current actual state, we recommend the use of the tester type 8201.
See the »Technical data« and the details in the individual brochures for the type 8546 current sensor and the type 8961 voltage-limiting device for further information on this unit.
Complete solutions in a wide variety of different configurations are available (please enquire).